International Standard Serial Number:

ISSN 1001-4551

Sponsor:

Zhejiang University;

Zhejiang Machinery and Electrical Group

Edited by:

Editorial of Journal of Mechanical & Electrical Engineering

Chief Editor:

ZHAO Qun

Vice Chief Editor:

TANG ren-zhong,

LUO Xiang-yang

Tel:

86-571-87041360,87239525

Fax:

86-571-87239571

Add:

No.9 Gaoguannong,Daxue Road,Hangzhou,China

P.C:

310009

E-mail:

meem_contribute@163.com

Design and implemention of automatic tour inspection system for fire pump
Published:2012-02-13 author:ZHANG Ji1, CHEN Tian-xiang1, SUN Yuan1, TIAN Hong1, NI Xue-yun2 Browse: 3214 Check PDF documents

Design and implemention of automatic tour inspection system for fire pump

ZHANG Ji1, CHEN Tian-xiang1, SUN Yuan1, TIAN Hong1, NI Xue-yun2
(1. Department of Electronic and Electrical Engineering, Xiamen University of Technology, Xiamen 361024, China;
2. Wuxi Wanbo Automation Co. Limited,Wuxi 214072, China)

Abstract: In order to prevent that fire pump cannot work because of corrosion at the time of fire occurrence,tour inspection system was developed based PLC control technology and frequency conversion technology. The fire safety problems of building and reliability of firewater supply system were analyzed to design tour inspection system.The tour inspection system was composed of Siematic S7-300,Siematic MM430 intelligent instrument,connected by PROFIBUS DP bus. The superior computer communicated with PLC based on MPI bus. Results show that the system gets good index of the high reliability,high automation,good expansibility and high stability,has a good prospect.
Key words: automatic tour inspection;manual inspection;superior computer ;fire pump

  • Chinese Core Periodicals
  • Chinese Sci-tech Core Periodicals
  • SA, INSPEC Indexed
  • CSA: T Indexed
  • UPD:Indexed

Copyright 2010 Zhejiang Information Institute of Mechinery Industry All Rights Reserved

Technical Support:Hangzhou Bory science and technology

You are 1895221 visit this site