JOURNAL OF MECHANICAL & ELECTRICAL ENGINEERING
Founded in 1971 >
Chinese Sci-tech Core Periodicals >
British Science Abstracts (SA, INSPEC) Indexed Journals >
United States, Cambridge Scientific Abstract: Technology (CSA: T) Indexed Journals >
United States, Ulrich's Periodicals Directory(UPD)Indexed Journals >
United States, Cambridge Scientific Abstract: Natural Science (CSA: NS) Indexed Journals >
Poland ,Index of Copernicus(IC) Indexed Journals >
International Standard Serial Number:
ISSN 1001-4551
Sponsor:
Zhejiang University;
Zhejiang Machinery and Electrical Group
Edited by:
Editorial of Journal of Mechanical & Electrical Engineering
Chief Editor:
ZHAO Qun
Vice Chief Editor:
TANG ren-zhong,
LUO Xiang-yang
Tel:
86-571-87041360,87239525
Fax:
86-571-87239571
Add:
No.9 Gaoguannong,Daxue Road,Hangzhou,China
P.C:
310009
E-mail:
meem_contribute@163.com
DC side short-circuit fault analysis of VSC
Published:2014-06-11
author:HU Jing-jing1,GAO Yi-bo1,YAN Yu-ting2,XV Xi-dong1
Browse: 3054
Check PDF documents
DC side short-circuit fault analysis of VSC
HU Jing-jing1,GAO Yi-bo1,YAN Yu-ting2,XV Xi-dong1
(1. School of Electrical Engineering,Zhejiang University,Hangzhou 310027,China;
2. Shenzhen Power Supply Bureau,Shenzhen 518020,China)
Abstract:As the fault voltage and current change raptly in case of DC side fault of voltage source converter(VSC),it's a serious threat to the whole system. Aiming at this problem,the mechanism of DC side short-circuit fault,which is the most serious DC side fault of VSC,was analyzed on power electronics level. The three stages of fault process were presented in detail. Firstly,fault voltage and current expressions of capacitor discharge stage were derived. Then,the existing two cases of the uncontrolled diode rectifier initial stage were
elaborated further. Moreover,the calculation of short-circuit current of the uncontrolled diode rectifier stable stage using switch function was proposed as well. Finally,theoretical analysis of the short-circuit fault process was validated through the PSCAD/EMTDC simulation of ±10 kV DC line. The results indicate that the response of the fault is related to the fault impedance closely. Quick removal of the fault needs to be done by DC circuit breaker instantly when the fault impedance is small,while backup protection could be obtained by dynamic monitoring voltages and currents in ac side using protection devices of ac side when the fault impedance is relatively large.
Key words:voltage source converter(VSC);short-circuit fault;PSCAD/EMTDC
-