JOURNAL OF MECHANICAL & ELECTRICAL ENGINEERING
Founded in 1971 >
Chinese Sci-tech Core Periodicals >
British Science Abstracts (SA, INSPEC) Indexed Journals >
United States, Cambridge Scientific Abstract: Technology (CSA: T) Indexed Journals >
United States, Ulrich's Periodicals Directory(UPD)Indexed Journals >
United States, Cambridge Scientific Abstract: Natural Science (CSA: NS) Indexed Journals >
Poland ,Index of Copernicus(IC) Indexed Journals >
International Standard Serial Number:
ISSN 1001-4551
Sponsor:
Zhejiang University;
Zhejiang Machinery and Electrical Group
Edited by:
Editorial of Journal of Mechanical & Electrical Engineering
Chief Editor:
ZHAO Qun
Vice Chief Editor:
TANG ren-zhong,
LUO Xiang-yang
Tel:
86-571-87041360,87239525
Fax:
86-571-87239571
Add:
No.9 Gaoguannong,Daxue Road,Hangzhou,China
P.C:
310009
E-mail:
meem_contribute@163.com
Analysis and solustion of the anti-tripping circuit on 10kV circuit breakers
Published:2014-09-04
author:LI Ying-cheng, CHAI Long-qing, GAO Zhen-xing, WANG Zhen-ning, WANG Hong-guang
Browse: 3418
Check PDF documents
Analysis and solustion of the anti-tripping circuit on 10kV circuit breakers
LI Ying-cheng, CHAI Long-qing, GAO Zhen-xing, WANG Zhen-ning, WANG Hong-guang
(State Grid Yantai Power Supply Company, Yantai 264000, China)
Abstract: Aiming at the problem that the circuit breaker can not switch on again, and a phenomenon that tripping and closing monitoring lights along with bright when we did the replacing and debugging test of 10 kV line protection devices in a Shandong 110kV transformer substation. After analyzing operating circuit of protection device and the secondary circuit of the switching mechanism, anti-tripping of NARIRELAYS RCS-9611C protection devices and Anti-jump switching mechanism of Qingdao Yi He was used simultaneously at the scene. A parasitic circuit was produced. A measure was proposed by accessing normally closed contact of the breaker and switch mechanism′s antitripping relay in closing monitoring circuit. Breaker was tested repeatedly using the opportunities of power failure and switch in the test position. The results show that the program is not only the perfect solution to the problem, while the quality of closing the circuit has been monitored.
Key words: anti-tripping circuit; closing monitoring circuit; protection anti-tripping; mechanical anti-tripping
-