JOURNAL OF MECHANICAL & ELECTRICAL ENGINEERING
Founded in 1971 >
Chinese Sci-tech Core Periodicals >
British Science Abstracts (SA, INSPEC) Indexed Journals >
United States, Cambridge Scientific Abstract: Technology (CSA: T) Indexed Journals >
United States, Ulrich's Periodicals Directory(UPD)Indexed Journals >
United States, Cambridge Scientific Abstract: Natural Science (CSA: NS) Indexed Journals >
Poland ,Index of Copernicus(IC) Indexed Journals >
International Standard Serial Number:
ISSN 1001-4551
Sponsor:
Zhejiang University;
Zhejiang Machinery and Electrical Group
Edited by:
Editorial of Journal of Mechanical & Electrical Engineering
Chief Editor:
ZHAO Qun
Vice Chief Editor:
TANG ren-zhong,
LUO Xiang-yang
Tel:
86-571-87041360,87239525
Fax:
86-571-87239571
Add:
No.9 Gaoguannong,Daxue Road,Hangzhou,China
P.C:
310009
E-mail:
meem_contribute@163.com
A redundant monitoring program based on VC++ and OPC
Published:2014-10-08
author:LIU Rui-xiang1,NI Fu-sheng2,3,GU Ming1
Browse: 3394
Check PDF documents
A redundant monitoring program based on VC++ and OPC
LIU Rui-xiang1,NI Fu-sheng2,3,GU Ming1
(1. CCCC Tianjin Dredging Co.,Ltd.,Tianjin 300461,China; 2. Engineering Research Center of Dredging
Technology of Ministry of Education,Hohai University,Changzhou 213022,China;3. College of Mechanical & Electrical Engineering,Hohai University,Changzhou 213022,China)
Abstract:Aiming at the low reliability problem of current monitoring system of a sand transport test stand,Siemens software redundancy technology,OPC technology and VC++ programming techniques were researched. The process and characteristics of the communication between the PLC lower machine and the monitoring program which were used in the monitoring system based on Siemens redundancy were generalized. A method was proposed to realize the communication between two monitoring computers and two S7-300 PLC stations
by using OPC technology. The SIMATIC NET software was used to build an OPC Server,and the redundant monitoring program was programed by VC++. The active CPU was identified by the monitoring system by judging the status flags of each active/standby CPU. The data in the active CPU was read and written. The stability and reliability of the monitoring program were tested by fault simulation experiments. The results show that all parameters are monitored in real time,the function of automatic switching of the active/standby system and the fault alarm are realized,and the monitoring system is stable and reliable.
Key words:sand transport;redundant system;OPC;VC++
-
- Chinese Core Periodicals
-
- Chinese Sci-tech Core Periodicals
-
- SA, INSPEC Indexed
-
- CSA: T Indexed
-
- UPD:Indexed
-