Noise analysis and filtering methods of dual energy Xray transmission system
Published:2015-10-10
author:YANG Bin1, YE Wenhua1, XIONG Tianzhong1,2, MAO Donghui1, WANG Qiao1, HU Pinlong3
Browse: 2878
Check PDF documents
Noise analysis and filtering methods of dual
energy Xray transmission system
YANG Bin1, YE Wenhua1, XIONG Tianzhong1,2,
MAO Donghui1, WANG Qiao1, HU Pinlong3
(1. College of Mechanical & Electrical Engineering, Nanjing University of Aeronautics and Astronautics,
Nanjing 210016, China; 2. College of Electrical & Automatic Engineering, Sanjiang University, Nanjing
210012, China; 3. Jiangsu Huahong Technology Stock Co.,Ltd., Jiangyin 214423, China)
Abstract: Aiming at the problem that the noise of the original dualenergy Xray transmission signal is very complicated and difficult to filter, the dualenergy Xray transmission signal acquisition and analysis system was established based on the operational principle of dualenergy Xray transmission separation technology. The sources and characteristics of background noise, isolated noise, circuit interconnect crosstalk noise and detection random noise contained in the original dualenergy Xray transmission signal were studied. The Gauss distribution of detection random noise, irregularity of isolated noise and the fixity of crosstalk noise between detection boards were researched, a new improved adaptive median filtering method based on the statistic of the neighborhood pixels was proposed. Dualenergy Xray transmission analysis experiment was tested on 6009 aluminum alloy block, the filtering effect of median filtering method and the proposed method was analyzed comparatively. The results indicate that the noise in the original dualenergy Xray transmission signal can be effectively filtered by the improved adaptive median filtering method.
Key words: dualenergy xray; noise; filtering; transmission