JOURNAL OF MECHANICAL & ELECTRICAL ENGINEERING
Founded in 1971 >
Chinese Sci-tech Core Periodicals >
British Science Abstracts (SA, INSPEC) Indexed Journals >
United States, Cambridge Scientific Abstract: Technology (CSA: T) Indexed Journals >
United States, Ulrich's Periodicals Directory(UPD)Indexed Journals >
United States, Cambridge Scientific Abstract: Natural Science (CSA: NS) Indexed Journals >
Poland ,Index of Copernicus(IC) Indexed Journals >
International Standard Serial Number:
ISSN 1001-4551
Sponsor:
Zhejiang University;
Zhejiang Machinery and Electrical Group
Edited by:
Editorial of Journal of Mechanical & Electrical Engineering
Chief Editor:
ZHAO Qun
Vice Chief Editor:
TANG ren-zhong,
LUO Xiang-yang
Tel:
86-571-87041360,87239525
Fax:
86-571-87239571
Add:
No.9 Gaoguannong,Daxue Road,Hangzhou,China
P.C:
310009
E-mail:
meem_contribute@163.com
Bush burning study on circulating pump motor of nuclear power station based on fault tree
Published:2015-12-10
author:LI Li, GUO Meng, HAN Chui huang, WANG Ai bin, JIA Si lin
Browse: 2925
Check PDF documents
Bush burning study on circulating pump motor
of nuclear power station based on fault tree
LI Li, GUO Meng, HAN Chui huang, WANG Ai bin, JIA Si lin
(China Nuclear Power Engineering Co., Ltd., Shenzhen 518124, China)
Abstract: Aiming at the circulating water pump motor′s guide bearing bush burning incident of Yangjiang Nuclear Power Station Unit 2, study on the cause of the incident was carried out from the perspective of equipment manufacturing quality, installation accuracy, working condition and personal operation. Based on fault tree analysis method, a fault tree of the incident was drawn and a series of basic events could be established and analyzed. By calculating the structure important degree from a qualitative perspective, the major events leading to the incident were found out. Combining with the investigation result, the cause of the incident was clear: no effective detection or monitoring was done to the bad working condition. Afterwards, this analysis was used as a guide for subsequent solution, and the major events were handled emphatically. At last, the incident was successfully resolved. On the other hand, there was some experience for the prevention of incident like this. The results of analysis and resolving indicate that fault tree is appropriate for this kind of incidents because of its correct analysis and emphatic measures.
Key words: circulating water pump; motor; bushburning; fault tree
-