International Standard Serial Number:

ISSN 1001-4551

Sponsor:

Zhejiang University;

Zhejiang Machinery and Electrical Group

Edited by:

Editorial of Journal of Mechanical & Electrical Engineering

Chief Editor:

ZHAO Qun

Vice Chief Editor:

TANG ren-zhong,

LUO Xiang-yang

Tel:

86-571-87041360,87239525

Fax:

86-571-87239571

Add:

No.9 Gaoguannong,Daxue Road,Hangzhou,China

P.C:

310009

E-mail:

meem_contribute@163.com

Influence of medium state change on cooling effect of ultra-low temperature valve
Published:2023-11-01 author:SUN Jing, XIA Chunwen, WANG Xinhao, et al. Browse: 356 Check PDF documents
Influence of medium state change on cooling effect of ultralow 
temperature valve


SUN Jing1, XIA Chunwen1, WANG Xinhao1, SHANG Yulin1, WANG Shuaishuai1, 
WANG Shouzhen2, WANG Shuai2, LIU Xin1

(1.School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, China; 
2.Dalian Marine Valve Co., Ltd., Dalian 116023, China)


Abstract: In-depth research on key technologies of ultra-low temperature valves has far-reaching impact on improving special valve technologies in China. When the temperature distribution of the ultra-low temperature valve was simulated, the analysis method used ignored the heat transfer between the low-temperature gas and the valve after the low-temperature medium absorbed the heat and underwent phase change.Therefore, taking Class300-DN65 ultra-low temperature cut-off valve as an example, the influence of medium state change and low temperature gas produced by phase change on valve cooling effect during steady-state operation was studied.Firstly, computational fluid dynamics (CFD) simulation of the medium flow process under adiabatic condition was performed, and a heat transfer model was established to explain the heat transfer process. Then, when heat transfer occurred, the internal clearance of the valve cover and the media distribution law of the flow field inside the valve were studied.Finally, the temperature distribution of the valve was analyzed by steady-state flow-thermal coupling.The research results show that the low temperature gas generated by evaporation and vaporization of LNG will flow at the bottom of the internal cavity of the valve cover, and constantly cool down the valve cover and stem by convective heat exchange, and the bottom temperature of the stuffing box is 10.6℃ when the effect of low temperature gas on the temperature field of the valve structure is not considered; but the bottom temperature of the stuffing box is only -0.2℃ when the low temperature gas is considered.Therefore, when designing the ultra-low temperature valves, it is necessary to consider the effect of cryogenic gas on the cooling of the valve, which otherwise may lead to seal failure.

Key words: flow control valve; ultra-low temperature stop valve; low-temperature medium; phase change; heat transfer; flowthermal coupling; vaporization; temperature distribution





  • Chinese Core Periodicals
  • Chinese Sci-tech Core Periodicals
  • SA, INSPEC Indexed
  • CSA: T Indexed
  • UPD:Indexed

Copyright 2010 Zhejiang Information Institute of Mechinery Industry All Rights Reserved

Technical Support:Hangzhou Bory science and technology

You are 1895221 visit this site